poyengineering.blogg.se

Konica minolta bizhub c452 staples
Konica minolta bizhub c452 staples








konica minolta bizhub c452 staples

The 2 staples trail edge stopper home sensor (PS22) is turned neither ON nor OFF even after the set period of time has elapsed after the 2 staples trail edge stopper motor (M19) is turned ON.Description: End stopper drive motor malfunction.3 PS11 I/O check, sensor check FSCB CN20-12 (ON) FS-526 L-12 4 M17 operation check FSCB CN18-1 to 2 FS-526 D-12 5 Change M17 - 6 FSCB ICP9 conduction check - 7 Change FSCB 2 Check the connector of M17 for proper drive coupling, and correct as necessary. Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary.Causes: Stacker plate motor (M17) Stacker plate home sensor (PS11) FS control board (FSCB).The stacker plate home sensor (PS11) is turned neither ON nor OFF even after the set period of time has elapsed while the stacker plate motor (M17) is energized.Description: Spare stacker board drive motor malfunction.3 PS16 I/O check, sensor check FSCB CN21-6 (ON) FS-526 L-7 4 M8 operation check FSCB CN14-1 to 4 FS-526 D-6 5 Change M8 - 6 Change FSCB 2 Check the connector of M18 for proper drive coupling, and correct as necessary. Causes: Rewind paddle motor (M18) Rewind paddle home sensor (PS16) FS control board (FSCB).The rewind paddle home sensor (PS16) is turned neither ON nor OFF even after the set period of time has elapsed after the rewind paddle motor (M18) is turned ON.Description: Side-staple rewinding paddle up-down motor malfunction.3 PS20 I/O check, sensor check FSCB CN21-3 (ON) FS-526 L-6 to 7 4 M15 operation check FSCB CN14-8 to 12 FS-526 D-5 5 Change M15 - 6 Change FSCB 2 Check the connector of M15 for proper drive coupling, and correct as necessary. Causes: Trail edge paddle motor (M15) Trail edge paddle home sensor (PS20) FS control board (FSCB).

konica minolta bizhub c452 staples

The trail edge paddle home sensor (PS20) is turned neither ON nor OFF even after the set period of time has elapsed after the trail edge paddle motor (M15) is turned ON.Description: Side-staple trailing paddle up-down motor malfunction.3 M16 operation check FSCB CN14-1 to 7 FS-526 D-5 4 Change M16 - 5 FSCB ICP13 conduction check - 6 Change FSCB 2 Check the connector of M16 for proper drive coupling, and correct as necessary. Causes: Paddle motor (M16) FS control board (FSCB).The paddle motor (M16) lock signal remains set to H for a set period of time while the paddle motor (M16) is turning.Description: Side-staple paddle roller motor malfunction.










Konica minolta bizhub c452 staples